éditions des archives contemporaines

Techno-economic assessment of solar power tower and solar parabolic dish system in India

  1. Heat Transfer and Thermal Power Laboratory, Department of Mechanical Engineering, Indian Institute of Technology, Madras Chennai, 600036
DOI10.17184/eac.9496 non déposé
Pages1–17
Paru le20 juin 2025
Citer Lire en PDF · 17 p.

Résumé

This article presents a techno-economic analysis and comparison between the solar power tower (SPT)
and the solar parabolic dish system (PDS) for Indian city of Jodhpur. Both of these technologies are integrated with
the Rankine cycle-based power block. The simulation is run for the power block in Cycle-Tempo software. The
thermal efficiency is obtained as 32%. With as the input, the technical and economic analyses are carried out. Four
economic parameters Net Present Value (NPC), Benefit-to-cost (B/C ratio), Discounted Payback Period (DPP) and
Levelized Electricity Cost (LEC) are used in the study. The NPV for SPT and PDS are 335.89 and 252.66 Cr. Rs.
Respectively. The B/C ratio obtained for SPT and PDS are 3.59 and 2.63 respectively. The DPP obtained for SPT
and PDS are 5.58 and 6.77 year respectively. The LEC achieved for SPT and PDS are1.89 and 2.30 Rs. / kWh
respectively. Finally, the sensitivity analysis considering various important parameters such as direct normal
irradiance (DNI), discounted interest rate and per square meter reflector cost is performed.

Mots clés
Solar power towerParabolic dish systemEnergy and economic analysesViabilitySensitivity analysis

Abstract

This article presents a techno-economic analysis and comparison between the solar power tower (SPT)
and the solar parabolic dish system (PDS) for Indian city of Jodhpur. Both of these technologies are integrated with
the Rankine cycle-based power block. The simulation is run for the power block in Cycle-Tempo software. The
thermal efficiency is obtained as 32%. With η<sub>th</sub>=32% as the input, the technical and economic analyses are carried out. Four economic parameters Net Present Value (NPC), Benefit-to-cost (B/C ratio), Discounted Payback Period (DPP) and Levelized Electricity Cost (LEC) are used in the study. The NPV for SPT and PDS are 335.89 and 252.66 Cr. Rs.
Respectively. The B/C ratio obtained for SPT and PDS are 3.59 and 2.63 respectively. The DPP obtained for SPT and PDS are 5.58 and 6.77 year respectively. The LEC achieved for SPT and PDS are1.89 and 2.30 Rs. / kWh respectively. Finally, the sensitivity analysis considering various important parameters such as direct normal irradiance (DNI), discounted interest rate and per square meter reflector cost is performed.

Keywords
Solar power towerParabolic dish systemEnergy and economic analysesViabilitySensitivity analysis

Lire l’article

Première page

PDF de 17 pages, tel qu’imprimé dans la revue, pages 1 à 17. En libre accès.